Lesson 3 3.9 Nuclear Fuel Performance in Reactors

A leaking fuel rod can sometimes be repaired, but more usually a replacement assembly is needed (with matching remaining enrichment level). Cost components include:

  • Cost of the replacement fuel assembly
  • Cost penalty and/or replacement power from reduced power operation or unscheduled shutdown
  • Higher operation and maintenance costs from mitigating increased radiation levels